CALL US

+86 17838360708

back to basics pump sizing

back to basics pump sizing

Back to Basics Pump Sizing - AIChE

Pump sizing, then, is the specification of the required outlet pressure of a rotodynamic pump (whose output flow ... Back to Basics a characteristic resistance coefficient, or value, which k can be found in Perry’s Handbook (1) and other sources (Table 1) (2).

get price

Pump Pt. 2 - Back to Basics Pump Sizing Bridging the Gap ...

View Pump Pt. 2.pdf from EPF 4801 at Universiti Putra Malaysia. Back to Basics Pump Sizing: Bridging the Gap Between Theory and Practice SEÁN MORAN EXPERTISE LTD. This article explains some of

get price

Pump Sizing 101 Pumps Systems

May 28, 2021  IMAGE 1: Plumbing fixture unit values (Image courtesy of Zoeller) Sizing a pump, in many cases, is an afterthought. Many installers have a go-to pump that has been used for decades without fail. Then it happens: After finishing up an installation, the pump is tested to ensure a job well done and nothing happens. The pump is running, but the water level is not moving.

get price

Back to Basics: Pumping Systems - rockymtnashrae

Back to Basics: Pumping Systems RM ASHRAE TECH CONFERENCE 1. 2 ... Pump/Pipe Sizing Corrections - Glycol . 33 Pump Selection •System curve •Best efficiency point •Max impeller size •Non-overloading •VFD, constant, or ride the curve •Future operation •NPSH .

get price

Back to Basics: Pumping Systems

Back to Basics: Pumping Systems RM ASHRAE TECH CONFERENCE 1. 2 AGENDA Pump Selection ... 80% back-up. •Check single pump operation for overloading and right end of curve operation •Use two similar pumps. 10 ... Expansion Tank Sizing Information needed: Vs=Volume of system

get price

Pump and piping sizing

The pump and the tube size or diameter are the 2 elements that typically can be changed. The bigger the pipe the easier it is to increase the flow rate within reason. It will not help you to go from a ½ in dia. tube to a 3 in pipe. Or maybe it would if you have completely mis-

get price

Sizing a Pump – Engineering Success

Aug 29, 2018  Sizing a pump at its basics is determining the pressure (commonly referred to as head) output of a pump necessary to provide a certain flow at a certain pressure downstream of the the pump. Since fluids are used all over from in factories to cool components to fire sprinklers systems to fight fires, pumps are everywhere too.

get price

Back to Basics Avoid Pressure-Relief System Pitfalls

Back to Basics based solely on the pump total dynamic head at zero flow — the suction pressure must be added to the total dynamic head to ensure the relief device is sized correctly. Centrifugal pumps in hot service may perform much differently during a cold startup — when outlets are more likely to become blocked — than they do under normal

get price

Back to Basics- Pump Coupling Selection WaterWorld

Sep 01, 2012  Pumps; Back to Basics- Pump Coupling Selection. ... or to allow room for the pump "back-pull-out" element to be replaced without moving the motor. Also, since allowable shaft misalignment is normally expressed in fractions of an angle (in degrees) a longer spacer will accommodate more parallel shaft offset than a shorter spacer or couplings ...

get price

Pump Sizing and Selection Made Easy - Chemical Engineering ...

Jan 01, 2018  Example 1. Pump Sizing and Selection. The following is a pump sizing problem to illustrate the calculations in this article. You are told to purchase a pump for your manufacturing facility that will carry water to the top of a tower at your facility. The pump is a centrifugal pump that will need to pump 800 gal/min when in normal operation.

get price

Back to Basics Pumps Systems

In-depth articles on pump industry issues; ... How best efficiency point affects sizing and operation. Pumps. ... SubscribeSubscribe to Back to Basics. Trending. Pumps. Understanding the Basics of Fire Pumps. The NFPA 20 standard provides guidance for fire pump design and installation.

get price

Back to Basics- Pump Coupling Selection WaterWorld

Sep 01, 2012  Pumps; Back to Basics- Pump Coupling Selection. ... or to allow room for the pump "back-pull-out" element to be replaced without moving the motor. Also, since allowable shaft misalignment is normally expressed in fractions of an angle (in degrees) a longer spacer will accommodate more parallel shaft offset than a shorter spacer or couplings ...

get price

Back To Basics

pump. Collapse of the inner liner is often hard to detect even when the inside of the hose is examined with a light. This is due to the fact that the inner liner often goes back in place when the suction vacuum is removed. If the pump will deliver capacity with a different

get price

HOW TO design a pump system

Example 1 - Sizing a pump for a home owner application Experience tells me that to fill a bath up in a reasonable amount of time, a flow rate of 10 gpm is required. According to Table 1, the copper tubing size should be somewhere between 1/2" and 3/4", I choose 3/4".

get price

How to do pump sizing by application Grundfos

Step 3: Choose your desired product. Choose a specific pump to review in-depth pump information. Select the print option if you would like to make a PDF of the pump and print the relevant data you need, such as sizing results, curve, duty points, installation and pump dimensions. Go to pump sizing

get price

Back to Basics: Compression Packing Pumps Systems

Oct 20, 2016  The goal of this article is to provide an overview of the critical steps necessary to ensure outstanding packing performance. The first step is to remember the “5 Ps of Packing Installation”: proper selection. preparation for installation. product form. placement. patience (and a

get price

Aeration 101 – Back to Basics

• Varies by bubble size, location in tank, flows • Typically 0.5-0.8 • Beta (Saturation Factor, ~0.98) • Theta (Temperature Correction Factor, ~1.024) • D.O. (Dissolved Oxygen Requirement, ~2.0 mg/L) • Temperature (°C) • Pressure / Elevation • Saturation (mg O 2/L) ( ) * 20 * 20 20. 9.07 sat surfT std site sat T C DO C P P C ...

get price

Back to basics: Acoustics - AIRAH

Back to basics: Acoustics HVAC installations for vibration reduction Presented by Clem Sturgess ... The spacing of pipework hangers is dependant on the size of the pipework, however, the pipework should be supported at all changes of direction. ... Install spring mounts on the pipe stand base so that they match pump spring deflection or

get price

Back to Basics: Compression Packing

sure the pump and accessories are properly prepared for installation of the packing. The stuffing box must be clean, and the worn-out packing must be completely removed. Leftover packing debris can create uneven seating, which can cause leakage or plug the flush port line and lead to overheating problems. Back to Basics: Compression Packing

get price

Condensate Return Pump and Receiver Sizing Tips: Steam ...

Apr 17, 2017  This segment of the steam and steam heat exchanger basics series explores condensate return units. The purpose of a condensate return unit or condensate return pump is to lift the condensate to overhead mains in order to get the water back to the boiler room and the boiler feeds pumping unit as fast as possible. Condensate Receiver Sizing

get price

An Engineering Guide to Modern Fuel Systems

deliver to the boiler mounted pumps at a very low pressure. This transfer pump must be over sized by a factor of 1.5-2 to accommodate the extra flow required by the onboard pumps. Always check the flow of the fuel pump supplied by the manufacturer. On some boilers there can be a 5 to 10 times factor for the pump size compared with the burn rate.

get price

Back To Basics Part II – Impact Of Impeller Trim On Pump ...

Oct 06, 2009  Back To Basics Part II – Impact Of Impeller Trim On Pump Efficiency. ... When a pump is controlled by a throttle valve, any throttling will increase the system friction head, which pushes the pump back on its Head-Capacity curve, as shown in figure 1. Now since power curves for most industrial pumps (with the exception of higher specific ...

get price

Consulting - Specifying Engineer Basics of boiler selection

Sep 15, 2017  Boiler feedwater pumps should be capable of supplying the boiler with water at a pressure at least 3% higher than that of the drum operating pressure. An evaluation of the line routing from the pump outlet to the drum inlet should be performed and pressure losses calculated to determine the proper discharge pressure.

get price

Steam Basics Part 15: Condensate Return Pump and Receiver ...

Apr 21, 2017  The purpose of a condensate return unit or condensate return pump is to lift the condensate to overhead mains in order to get the water back to the boiler room and the boiler feed pumping unit as fast as possible. The receiver is typically made from cast iron or steel. We usually recommend cast iron; the budget can stand the slight increase in ...

get price

Back to Basics - Excel Engineering, Inc.

Basics of Flow With Pumps Wayne Salo, PE Page 6 2.1.4. Efficiency (See Chart in Section 2.1) The manufacturers chart will also include efficiencies (green lines) associated with flow and pressure for that particular pump. For each pump model/style/size the manufacturer has identified and charted the mechanical pump efficiency.

get price

Back to Basics: What Makes a Good Pump Turbomachinery blog

Feb 23, 2021  Back to Basics: What Makes a Good Pump? Posted Tuesday, February 23, 2021 Tuesday, ... of the main parameters of the pump on the flow and head at a certain viscosity and density of the liquid and the size of the impeller. On these characteristics, two main types of work can be distinguished: economic, where the maximum efficiency takes place ...

get price

How to do pump sizing by application Grundfos

Step 3: Choose your desired product. Choose a specific pump to review in-depth pump information. Select the print option if you would like to make a PDF of the pump and print the relevant data you need, such as sizing results, curve, duty points, installation and pump dimensions. Go to pump sizing

get price

Aeration 101 – Back to Basics

• Varies by bubble size, location in tank, flows • Typically 0.5-0.8 • Beta (Saturation Factor, ~0.98) • Theta (Temperature Correction Factor, ~1.024) • D.O. (Dissolved Oxygen Requirement, ~2.0 mg/L) • Temperature (°C) • Pressure / Elevation • Saturation (mg O 2/L) ( ) * 20 * 20 20. 9.07 sat surfT std site sat T C DO C P P C ...

get price

6 Basic Rules of Pump Piping - Crane Engineering

After carefully selecting the right size and materials, make sure the new pump is set up for success with proper installation. Setting the base correctly and aligning the pump is crucial. It’s also extremely important that piping to the pump is done properly. Pump piping design is sometimes overlooked when setting up new installations.

get price

Fall Capsule Wardrobe: Back to Basics - The Golden Girl

Sep 17, 2019  Sizing: Run TTS. I wear size 25, and I’m 5’6 for height reference. #5: Editor Heel . If you love the look of a sleek, classic pump but aren’t a big fan of heels, you will love these. The heels are very low and manageable, and I adore the square detail that shoes the perfect amount of toe cleavage.

get price

Back To Basics Part II – Impact Of Impeller Trim On Pump ...

Oct 06, 2009  Back To Basics Part II – Impact Of Impeller Trim On Pump Efficiency. ... When a pump is controlled by a throttle valve, any throttling will increase the system friction head, which pushes the pump back on its Head-Capacity curve, as shown in figure 1. Now since power curves for most industrial pumps (with the exception of higher specific ...

get price

Back to Basics: Compression Packing

sure the pump and accessories are properly prepared for installation of the packing. The stuffing box must be clean, and the worn-out packing must be completely removed. Leftover packing debris can create uneven seating, which can cause leakage or plug the flush port line and lead to overheating problems. Back to Basics: Compression Packing

get price

Water Piping and Pumps - Sigler Commercial

Oct 02, 2017  means the pump and pump energy is larger than other distri-bution systems of comparable size. History of 1-Pipe Systems The 1-pipe system has been used for many years in residential and smaller commercial buildings. It has been used as a hot water distribution system and seldom, if ever, for the distribution of chilled water. Figure 4

get price

Back to basics: VRF systems - Consulting-Specifying Engineer

Sep 27, 2016  The VRF heat pump system provides heating and cooling for all indoor units at a specific time (see Figure 1) The VRF system provides nonsimultaneous cooling and heating at any time. Heat-recovery systems provide simultaneous cooling and heating as well as heat recovery, transferring the energy from cooling zones to heating zones of the building.

get price

Air Valves in Piping Systems - Valve Magazine

Liquid piping systems are prone to collecting air from incoming fluids, pumps and connections. This air can cause inefficiencies and serious operating problems. Last year, VALVE Magazine published “Why Air Valves are Needed in Water Applications,” which outlined the sources and effects of air in pipelines. This article explains how the various types of air valves operate in liquid piping ...

get price

Sump and Sewage Ejector Systems The (Not So) Basics 2008 ...

Feb 01, 2008  When it comes to systems using submersible pumps, a large access opening is inherent for each pump; 18 inches round per pump in most cases. This is a 1/2-hp submersible sewage pump, the Model LE51A. It features all-cast-iron construction and 2-inch solids-handling capabilities. Photo courtesy of Liberty Pumps, Inc.

get price

Back to Basics: Rifle Stocks—Part 1 American Rifleman ...

Feb 15, 2017  Back to Basics: Rifle Stocks—Part 1. Like most firearms and their components, rifle stocks have gone through a profound revolution during the

get price

Positive Displacement Pump Basics - Fristam

Positive Displacement Pump Basics A. Definitions and Terms Density Density is the mass of a substance per unit volume. Generally, we express density in units of pounds per ... The differential pressure that the pump must gen-erate is key to sizing. Differential pressure is the total pressure against which a pump must work.